6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)(2)(5)
|
MIN |
MAX |
UNIT |
HVIN |
|
–0.3 |
700 (3) |
V |
DRAIN |
|
Internally clamped |
700(3) |
V |
IDRAIN |
Positive drain current single pulse, pulse max duration 25 μs |
|
320(6) |
mA |
IDRAIN |
Negative drain current |
–320 |
|
mA |
FB |
|
–0.3 |
6 |
V |
VDD |
VDD is supplied from low impedance source |
–0.3 |
6 |
V |
IVDD |
VDD is supplied from high impedance source |
|
400 |
µA |
TJ(4) |
Junction temperature |
|
150 |
°C |
|
Lead temperature 1.6 mm (1/16 inch) from case 10 seconds |
|
260 |
°C |
Tstg |
Storage temperature range |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND. Currents are positive into, negative out of the specified terminal. These ratings apply over the operating ambient temperature ranges unless otherwise noted.
(3) TA = 25°C
(4) The thermal shutdown threshold can be beyond the absolute maximum rating of the junction temperature. Thermal shut down is designed to prevent thermal run away that could result in catastrophic failure. Prolonged operation above recommended maximum junction temperature can impact device life time
(5) The device is not rated to withstand operating conditions when multiple parameters are at or near, absolute maximum ratings.
(6) The MOSFET drain to source voltage is less than 400V
6.2 ESD Ratings
|
UNIT |
V(ESD) |
Electrostatic discharge |
Human Body Model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins except HVIN pin(1) |
±2000 |
V |
Human Body Model (HBM) per ANSI/ESDA/JEDEC JS-001, HVIN pin (1) |
±1500 |
V |
Charged device model (CDM), per JEDEC specification JESD22-C101, all pins(2) |
±500 |
V |
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.