JAJSD23C February   2017  – February 2018 TVS3300

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     Device Images
      1.      占有面積の比較
      2.      8/20rep%#181;sのサージ・イベントに対する電圧クランプの応答
  4. 改訂履歴
  5. Device Comparison Table
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings - JEDEC
    3. 7.3 ESD Ratings - IEC
    4. 7.4 Recommended Operating Conditions
    5. 7.5 Thermal Information
    6. 7.6 Electrical Characteristics
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Reliability Testing
    5. 8.5 Device Functional Modes
      1. 8.5.1 Protection Specifications
      2. 8.5.2 Minimal Derating
      3. 8.5.3 Transient Performance
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 PLC Surge Protection Reference Design
      4. 9.2.4 Configuration Options
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12デバイスおよびドキュメントのサポート
    1. 12.1 ドキュメントのサポート
      1. 12.1.1 関連資料
    2. 12.2 ドキュメントの更新通知を受け取る方法
    3. 12.3 コミュニティ・リソース
    4. 12.4 商標
    5. 12.5 静電気放電に関する注意事項
    6. 12.6 Glossary
  13. 13メカニカル、パッケージ、および注文情報

Absolute Maximum Ratings

TA = 27℃ (unless otherwise noted)(1)
MIN MAX UNIT
Maximum Surge IEC 61000-4-5 Current (8/20 µs) 35 A
IEC 61000-4-5 Power (8/20 µs) 1330 W
IEC 61643-321 Current (10/1000 µs) - WCSP 4 A
IEC 61643-321 Power (10/1000 µs) - WCSP 150 W
IEC 61643-321 Current (10/1000 µs) - DRV 3.5 A
IEC 61643-321 Power (10/1000 µs) - DRV 125 W
Maximum Forward Surge IEC 61000-4-5 Current (8/20 µs) 50 A
IEC 61000-4-5 Power (8/20 µs) 80 W
IEC 61643-321 Current (10/1000 µs) 23 A
IEC 61643-321 Power (10/1000 µs) 60 W
EFT IEC 61000-4-4 EFT Protection 80 A
IBR DC Breakdown Current - DRV 10 mA
IF DC Forward Current 500 mA
TA Ambient Operating Temperature -40 125 °C
Tstg Storage Temperature -65 150 °C
Stresses beyond those listed under Absolute Maximum Rating may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Condition. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.