JAJSDZ9 October 2017 ADS54J64
PRODUCTION DATA.
The second-stage filter is used for decimating the data from a sample rate of fCLK / 2 to fCLK / 4. Figure 52 and Figure 53 show the frequency response and pass-band ripple of the second-stage filter, respectively.
Input clock rate (fCLK) = 1 GHz |