7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
|
|
MIN |
MAX |
UNIT |
VS |
Total supply voltage (VS+ – VS–) |
|
5.5 |
V |
VIN+, VIN– |
Input voltage |
(VS–) – 0.5 |
(VS+) + 0.5 |
VID |
Differential input voltage |
|
1 |
VOUT |
Output voltage |
(VS–) – 0.5 |
(VS+) + 0.5 |
IIN |
Continuous input current |
|
±10 |
mA |
IOUT |
Continuous output current(2) |
|
±100 |
TJ |
Junction temperature |
|
150 |
°C |
TA |
Operating free-air temperature |
|
125 |
TSTG |
Storage temperature |
–65 |
150 |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Long-term continuous output current for electromigration limits.