Set the turns ratio of the transformer secondary windings using Equation 29, where NS1 and NS2 are the number of secondary turns for the respective outputs.
Choose a primary-secondary turns ratio for the 15-V output based on an approximate 60% max duty cycle at minimum input voltage using Equation 30. The transformer turns ratio for both outputs is thus specified as 1 : 1 : 0.52.
Select a magnetizing inductance based on the minimum off-time constraint using Equation 31. Choose a value of 30 µH with a saturation current of 2 A for this application.