JAJSM76E December 2015 – August 2022 LMX2582
PRODUCTION DATA
The ideal input is a low-noise, 200-MHz (or multiples of it) signal and 200-MHz phase detector frequency (highest dual PFD frequency). However, if spur mechanisms are understood, certain combinations of the R-divider and Multiplier can help. Refer to the Section 8.1.1 section for understanding spur types and their mechanisms first, then try this section for these specific spurs.