Over the recommended operating junction temperature range of –40°C to 175°C (unless otherwise noted)(1)(2)
PARAMETER |
MIN |
MAX |
UNIT |
Voltage |
VIN to GND |
–0.3 |
70 |
V |
EN to GND |
–0.3 |
70 |
V |
SW to GND |
–0.3 |
70.3 |
V |
PGOOD to GND |
0 |
20 |
V |
VOUT/BIAS to GND (Fixed output) |
–0.3 |
16 |
V |
FB to GND - (Adjustable output) |
–0.3 |
16 |
V |
BOOT to SW |
–0.3 |
5.5 |
V |
VCC to GND |
–0.3 |
5.5 |
V |
RT to GND (RT variant) |
–0.3 |
5.5 |
V |
MODE/SYNC to GND (MODE/SYNC variant) |
–0.3 |
5.5 |
V |
TJ |
Junction temperature (2) |
–40 |
175 |
°C |
Tstg |
Storage temperature |
–65 |
175 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) High junction temperatures degrade operating lifetimes. Operating lifetime is derated for junction temperatures greater than 175℃. See
Section 8.1.1 for more information.