The purpose of the output discharge function
is to make sure of a defined down-ramp of the output voltage when the device is disabled
and to keep the output voltage close to 0V. The output discharge is active when the
Enable Output Discharge bit is set to 1 and the EN pin is pulled low, when the Input
voltage is below the UVLO threshold or during thermal shutdown. The discharge is active
down to an input voltage of 1.6V (typical). The Enable Output Discharge bit is reset on