JAJU510H March 2018 – December 2022
This section shows the results obtained from the power analyzer as the load is slowly increased to 3.2 kW. The Figure 3-46 shows the steady state performance of PFC at 3.2 kW output power. Scope signals: Channel 1 - AC voltage (blue), Channel 2 - DC link voltage (light green), Channel 3 - AC current (dark green).
The results in Figure 3-46 are captured at 50 Hz but these can be verified at 60 Hz as well.
Figure 3-47 shows power key efficiency and THD figures captured at 3.2 kW.
INPUT AC VOLTAGE | OUTPUT DC VOLTAGE | OUTPUT DC CURRENT | OUTPUT POWER (W) | EFFICIENCY (%) | AVERAGE THD (%) | POWER FACTOR |
---|---|---|---|---|---|---|
120 | 608.26 | 0.19 | 116 | 78.61 | 39.33 | 0.81 |
120 | 608.36 | 1.54 | 936.7 | 94.9 | 5.8 | 0.995 |
120 | 608.15 | 2.13 | 1295 | 95.39 | 4.35 | 0.997 |
120 | 608.26 | 3.45 | 2100 | 95.71 | 2.71 | 0.998 |
120 | 608.26 | 4.85 | 2949 | 95.37 | 1.91 | 0.999 |
120 | 608.24 | 5.2 | 3165.7 | 95.29 | 1.85 | 0.999 |