Short jumper J1 for over voltage clamping or short jumper J3 for over voltage
cut-off.
Connect Latch header in J2 to VCC (TP6) for latched mode.
Latched mode requires J2 to be pulled low for at least 100ns to toggle the LATCH
pins of the INA302 device to clear the alert and for LM74810 to become
enabled.
Connect J4 to voltmeter to be able to read current sensed by INA302.
Connect power supply to input lug
connectors. Nominal voltage is 12 V. The power supply must be able to source up
to 60A to trigger default over current conditions of the design.
Connect electronic load to output lug. The electronic load must be able to sink
up to 60A and the corresponding power rating.