Switches U2, U3, and U4 can be disabled to reduce
current consumption when protection against external magnetic fields is not
necessary.
The different switches can be disabled by performing the following:
- Disabling U2: Remove resistor R21. Move
the 0-Ω resistor on the 3-pad R16 footprint from pads 2 and 3 to pads 1 and
2.
- Disabling U3: Remove resistor R20. Move
the 0-Ω resistor on the 3-pad R18 footprint from pads 2 and 3 to pads 1 and
2.
- Disabling U4: Remove resistor R19. Move
the 0-Ω resistor on the 3-pad R17 footprint from pads 2 and 3 to pads 1 and
2.
The switches can be enabled again by doing the following:
- Enabling U2: Place a 0-Ω
resistor at R21. Move the 0-Ω resistor on the 3-pad R16 footprint from pads 1
and 2 to pads 2 and 3.
- Enabling U3: Place a 0-Ω
resistor at R20. Move the 0-Ω resistor on the 3-pad R18 footprint from pads 1
and 2 to pads 2 and 3.
- Enabling U4: Place a 0-Ω
resistor at R19. Move the 0-Ω resistor on the 3-pad R17 footprint from pads 1
and 2 to pads 2 and 3.