SBAA321A January   2019  – June 2024 AMC1311 , AMC1411 , ISO224

 

  1.   1
  2.   2
  3.   Trademarks

Design Goals

Voltage Source ISO224 Input Voltage ISO224 Output Voltage VDD2 / 2 Common Mode (VOUTP – VOUTN) Power Supplies
VMAX VMIN VIN, MAX VIN, MIN VOUT, MAX VOUT, MIN VDD1 VDD2
480V –480V 12V –12V 4V –4V 4.5V–18V 4.5V–5.5V

Design Description

This circuit performs a ±480V, isolated, voltage-sensing measurement utilizing the ISO224 isolated amplifier and a voltage-divider circuit. The voltage-divider circuit reduces the voltage from ±480V to ±12V which matches the input range of the ISO224. The ISO224 is powered from both a high and low side power supply. Typically, the high side supply is generated using a floating supply or from the low side using an isolated transformer or isolated DC/DC converter. The ISO224 can measure single-ended signals of ±12V with a fixed gain of ⅓V/V and produces an isolated differential output voltage of ±4V with an output common-mode voltage of VDD2 / 2. The differential output voltage can be scaled as required using an additional operational amplifier such as the TLV6001 as shown in SBOA274 to interface with an ADC.

Design Notes

  1. Verify the systems linear operation for the desired input signal range. This is verified using simulation in the DC Transfer Characteristics section.
  2. Verify that the resistors used in the resistor divider circuit (R1–R5) are capable of dissipating the power supplied from the voltage source.
  3. Verify that the voltage on the input of the ISO224 is less than ±15V as stated in the absolute maximum ratings table of the data sheet and make sure that less than ±10mA is applied to the input. If the system is susceptible to transients, consider adding a TVS diode to the input. See the I-V Curve of the Input Clamp Protection Circuit image in the ISO224 Reinforced Isolated Amplifier with Single-Ended Input of ±12 V and Differential Output of ±4 V data sheet for additional details.

Design Steps

  1. Calculate the ratio from the voltage source to the input of the ISO224 for the voltage-divider circuit.
    12 V I S O 224 , I N P U T 480 V = 0.025
  2. The typical input impedance of the ISO224 is 1.25MΩ. This impedance is in parallel with resistor R5 and must be considered when designing the voltage-divider circuit. Select 1MΩ resistors for R1, R2, R3, and R4. Using the ratio from the previous step and the following voltage-divider equation, solve for the equivalent resistance required for the voltage-divider parallel combination ( || ) of R5 and the ISO224 input impedance.
    R 5 | | R I N , I S O 224 R 1 + R 2 + R 3 + R 4 + R 5 | |   R I N , I S O 224 = 0.025
    R 5 | | R I N , I S O 224 4 M Ω + R 5 | |   R I N , I S O 224 = 0.025
    R 5 | |   R I N , I S O 224 = 102564 Ω = R E Q
  3. Substituting 1.25MΩ for the ISO224 input impedance and using the following equation, solve for R5. Use the analog engineer's calculator to determine the closest standard value for R5.
    R E Q = 102564 Ω = R 5 × R I N , I S O 224 R 5 + R I N , I S O 224 = R 5 × 1.25 M Ω R 5 + 1.25 M Ω
    102564 Ω R 5 + 1.25 M Ω = R 5 × 1.25 M Ω
    R 5 = 1 11 . 73 k Ω ; c l o s e s t   s t a n d a r d   v a l u e = 111 k Ω
  4. Verify that the equivalent resistance is close to the calculated resistance from step 2.
    R E Q = R 5 × R I N , I S O 224 R 5 + R I N , I S O 224 = 111 k Ω × 1.25 M Ω 111 k Ω + 1.25 M Ω = 101.947 k Ω
  5. Verify that the voltage-divider circuit is within a reasonable error tolerance. For the following calculation, the input resistance of the ISO224 is assumed to be the typical value of 1.25MΩ and this results in an error of 0.6%. However, it is important to consider that the input resistance varies from device to device due to variations in the resistance of the internal clamp protection circuit. If the same calculation is performed using the minimum input resistance of 1MΩ, the error is 2.5%. If this error range is unacceptable then either a calibration must be performed or the resistance of the voltage-divider circuit can be scaled down.
    101.947 k Ω 4.101947 M Ω = 0.02485
    E r r o r % = A c t u a l - C a l c u l a t e d C a l c u l a t e d × 100 = 0.02485 - 0.025 0.025 × 100 = 0.6 %
  6. Calculate the current flowing through the voltage-divider circuit from the voltage source to make sure that the power dissipation does not exceed the ratings of the resistor. For additional details, see Considerations for High Voltage Measurements.
    V = I R ;   V R = 480 V 4 M Ω + 111 k Ω = 117 μ A

DC Transfer Characteristics

The following graph shows the simulated output for a ±600V input. The voltage divider scales the gain by 1/40, and the ISO224 scales the gain by an additional ⅓.

The transfer function shows the system gain is 1/40 from the voltage divider and ⅓ from the ISO224 (that is, gain × VIN = VOUT, (1/40) × (⅓) × (480V) = 4V).

AC Transfer Characteristics

The simulated gain is –41.58dB (or 0.008337V/V) which closely matches the expected gain for the voltage divider and ISO224.

References

  1. Analog Engineer's Circuit Cookbooks
  2. SPICE Simulation File SBAC232
  3. TI Precision Designs TIDA-00835
  4. TI Precision Labs

Design Featured Isolated Op Amp

ISO224B
VDD1 4.5V–18V
VDD2 4.5V–5.5V
Input Voltage Range ±12V
Nominal Gain
VOUT Differential ±4V on output common mode of VDD2 / 2
Input Resistance 1.25MΩ (typ)
Small Signal Bandwidth 275kHz
Input Offset Voltage and Drift ±5mV (max), ±15µV/°C (max)
Gain Error and Drift ±0.3% (max), ±35ppm/°C (max)
Nonlinearity and Drift 0.01% (max), ±0.1ppm/°C (typ)
Isolation Transient Overvoltage 7kVPEAK
Working Voltage 1.5kVRMS
Common-mode transient immunity, CMTI 55 kV/µs (min)
ISO224

Design Alternate Isolated Op Amp

AMC1311B
VDD1 3V–5.5V
VDD2 3V–5.5V
Input Voltage range 2V
Nominal Gain 1
VOUT Differential ±2V on output common mode of 1.44V
Input Resistance 1GΩ (typ)
Small Signal Bandwidth 220kHz
Input Offset Voltage and Drift ±1.5mV (max), ±15µV/°C (max)
Gain Error and Drift ±0.3% (max), ±45ppm/°C (max)
Nonlinearity and Drift 0.01%, 1ppm/°C (typ)
Isolation Transient Overvoltage 7kVPEAK
Working Voltage 1.5kVRMS
Common-mode transient immunity, CMTI 75kV/µs (min)
AMC1311