SBAS895B May 2018 – April 2020
PRODUCTION DATA.
Do not leave the inputs of the AMC1300 unconnected (floating) when the device is powered up. If both device inputs are left floating, the input bias current drives these inputs to the output common-mode of the analog front-end of approximately 2 V. If the high-side supply voltage VDD1 is below 4 V, the internal common-mode overvoltage detector turns on and the output functions as described in the Fail-Safe Output section, which may lead to an undesired reaction on the system level.