As illustrated in Figure 2-1, for a low-side measurement, connect the electronic load positive input
terminal to the positive terminal of a supply capable of sourcing the desired
amount of maximum load current. For a high-side measurement, connect the
electronic load positive input terminal to the load sourcing terminal (IN+ or
IN–) of the EVM. For high-side measurement of forward current, IN– sources to
the electronic load; for reverse current, IN+ sources to the load.
Connect the electronic load negative output terminal to the external supply GND terminal for high-side measurements, or to the load sinking terminal of the EVM for low-side measurements.
For high-side measurements, connect the external supply to the load sinking terminal of the EVM. Otherwise, for low-side measurements, connect the load sourcing terminal of the EVM (IN+ or IN–) to the external supply GND.
Turn on all the connected supplies.
Apply load with electronic load or actual system load.
Measure the output voltage at the test point for
the VOUT pin of the DUT.
Note: