SFFS550 March 2024 OPA2607-Q1 , OPA607-Q1
This section provides functional safety failure in time (FIT) rates for the DGK package of the OPAx607-Q1 based on two different industry-wide used reliability standards:
FIT IEC TR 62380 / ISO 26262 | FIT (Failures Per 109 Hours) |
---|---|
Total component FIT rate | 5 |
Die FIT rate | 2 |
Package FIT rate |
3 |
The failure rate and mission profile information in Table 2-3 comes from the reliability data handbook IEC TR 62380 / ISO 26262 part 11:
Table | Category | Reference FIT Rate | Reference Virtual TJ |
---|---|---|---|
4 |
BICMOS Op Amp, Comparators, Voltage Monitors |
4 FIT | 45°C |
The reference FIT rate and reference virtual TJ (junction temperature) in Table 2-4 come from the Siemens Norm SN 29500-2 tables 1 through 5. Failure rates under operating conditions are calculated from the reference failure rate and virtual junction temperature using conversion information in SN 29500-2 section 4.