SFFS624 March 2024 MSPM0G3105 , MSPM0G3105-Q1 , MSPM0G3106 , MSPM0G3106-Q1 , MSPM0G3107 , MSPM0G3107-Q1 , MSPM0G3505 , MSPM0G3505-Q1 , MSPM0G3506 , MSPM0G3506-Q1 , MSPM0G3507 , MSPM0G3507-Q1
In this test method, DAC is setup as per application configuration, the output of DAC is monitored using ADC. Anytime DAC values are updated, ADC has to be triggered allowing for DAC settling time and the ADC output can be checked against the expected value.