The software features are:
- Measurement of root mean square voltage, root mean square current, active power, reactive power, apparent power, power factor, AC frequency, voltage THD, current THD, fundamental voltage, fundamental current, fundamental active power
- Readings update every 4 AC cycles or 80 ms in case of DC input
- Capable of AC and DC measurement
- Capable of switching between AC and DC measurement mode automatically
- Capable of doing EMI filter capacitor and wire resistance compensation
- No separate DC calibration required