SLAU472C February 2013 – November 2023 TAS2505 , TAS2505-Q1
The TAS2505 allows the user to set the common mode voltage for analog inputs to 0.75V or 0.9V by programming Page 1, Register 10, D(6). The input common-mode voltage of 0.9V works best when the analog supply voltage is centered around 1.8V or above, and offers the highest possible performance. For analog supply voltages below 1.8V, a common mode voltage of 0.75V must be used.
Input Common Mode Voltage (V) | AVdd (V) | Channel Gain (dB) | Single-Ended Input Swing for 0dBFS output signal (VRMS) | Differential Input Swing for 0dBFS output signal (VRMS) |
---|---|---|---|---|
0.75 | >1.5 | –2 | 0.375 | 0.75 |
0.90 | 1.8 … 1.95 | 0 | 0.5 | 1.0 |