SLAZ370Q October 2012 – May 2021 MSP430FG477
LCDA Module
Functional
Wrong cycle time for first cycle of COMx/Sx signals
The time of the first cycle of COMx/Sx signals after enabling the LCD_A module is only half of the selected value. All following cycles are correct
Not required, because it does not influence the LCD function.