Adjusting Output Voltage (R1)

The regulated output voltage can be adjusted within a limited range by changing the ground resistor in the feedback resistor divider (R1). The output voltage is given by Equation 1.

Equation 1. VOUT= VVREF × R5+R1R1

where

  • VVREF = 0.591 V
  • R5 = 10 kΩ

Table 3-1 contains common values for R1 to generate popular output voltages. The TPS40190EVM-001 is stable through these output voltages but the efficiency can suffer as the power stage is optimized for the 1.5-V output.

Table 3-1 Adjusting VOUT with R1
VOUT R1
3.3 V(1) 2.15 k
2.5 V(1) 3.09 k
2.25 V 3.57 k
2.0 V 4.22 k
1.8 V 4.87 k
1.5 V 6.49 k
1.2 V 9.76 k
For output voltages greater than 2.5 V, change C11 to 330 μF, 4 V or higher PosCAP.