SLUU367A
July 2009 – February 2022
TPS51163
Trademarks
1
Introduction
2
Description
3
Typical Applications
4
Features
5
Electrical Performance Specifications
6
Schematic
7
Test Setup
7.1
Test Equipment
7.1.1
Voltage Source
7.1.2
Multimeters
7.1.3
Output Load
7.1.4
Oscilloscope
7.1.5
Fan
7.1.6
Recommended Wire Gauge
7.2
Recommended Test Setup
7.2.1
Input Connections
7.2.2
Output Connections
7.2.3
Other Connections
8
Test Procedure
8.1
Line/Load Regulation and Efficiency Measurement Procedure
8.2
Control Loop Gain and Phase Measurement Procedure
8.3
List of Test Points
8.4
Equipment Shutdown Procedure
9
Performance Data and Typical Characteristic Curves
10
EVM Assembly Drawing and PCB layout
11
List of Materials
12
References
13
Revision History
8.1
Line/Load Regulation and Efficiency Measurement Procedure
Ensure that the load is set to constant resistance mode and to sink 0 Adc.
Ensure that the jumper provided in the EVM to short on JP1 before V
IN
is applied.
Increase V
IN
from 0 V to 12 V, using V1 to measure input voltage.
Remove the jumper on JP1 to enable the controller.
Vary load from between 0 VAdc and 10 Adc, V
OUT
should remain in load regulation.
Vary V
IN
from 8 V to 14 V. V
OUT
should remain in line regulation.
Put the jumper on JP1 to disable the controller.
Decrease the load to 0 A.
Decrease V
IN
to 0 V.