SLUU367A July   2009  – February 2022 TPS51163

 

  1.   Trademarks
  2. Introduction
  3. Description
  4. Typical Applications
  5. Features
  6. Electrical Performance Specifications
  7. Schematic
  8. Test Setup
    1. 7.1 Test Equipment
      1. 7.1.1 Voltage Source
      2. 7.1.2 Multimeters
      3. 7.1.3 Output Load
      4. 7.1.4 Oscilloscope
      5. 7.1.5 Fan
      6. 7.1.6 Recommended Wire Gauge
    2. 7.2 Recommended Test Setup
      1. 7.2.1 Input Connections
      2. 7.2.2 Output Connections
      3. 7.2.3 Other Connections
  9. Test Procedure
    1. 8.1 Line/Load Regulation and Efficiency Measurement Procedure
    2. 8.2 Control Loop Gain and Phase Measurement Procedure
    3. 8.3 List of Test Points
    4. 8.4 Equipment Shutdown Procedure
  10. Performance Data and Typical Characteristic Curves
  11. 10EVM Assembly Drawing and PCB layout
  12. 11List of Materials
  13. 12References
  14. 13Revision History

Recommended Test Setup

Figure 7-2 is the recommended test setup to evaluate the TPS51163EVM. Working at an ESD workstation, make sure that any wrist straps, bootstraps, or mats are connected referencing the user to earth ground before power is applied to the EVM.

GUID-E02A7ACD-4BD9-41EB-BE0A-4148FEE4FBC7-low.pngFigure 7-2 TPS51163EVM Recommended Test Setup