SLUUA65E april 2014 – june 2023 BQ28Z610
The device can permanently disable the battery pack in case of a voltage difference between the cells in a stack while at rest.
Status | Condition | Action |
---|---|---|
Normal | CellVoltage0..1() < VIMR:Check Voltage OR |Current()| > VIMR:Check Current OR Δ(CellVoltage0..1()) < VIMR:Delta Threshold | PFAlert()[VIMR] = 0 |
Alert | Any(CellVoltage0..1()) ≥ VIMR:Check Voltage AND |Current()| < VIMR:Check Current for VIMR:Duration AND Δ(CellVoltage0..1()) ≥ VIMR:Delta Threshold | PFAlert()[VIMR] = 1 |
Trip | Any(CellVoltage0..1()) ≥ VIMR:Check Voltage AND |Current()| < VIMR:Check Current for VIMR:Duration AND Δ(CellVoltage0..1()) ≥ VIMR:Delta Threshold for VIMR:Delta Delay | PFAlert()[VIMR] = 0 PFStatus()[VIMR] = 1 BatteryStatus()[TCA] = 1 BatteryStatus()[TDA] = 1 |