Total firmware Runtime starts when Lifetime Data is enabled.
- Voltage
- Max/Min Cell Voltage Each Cell
- Max Delta Cell Voltage at any given time (that is, the max cell imbalance voltage)
- Current
- Max Charge/Discharge Current
- Max Average Discharge Current
- Max Average Discharge Power
- Safety Events that trigger the SafetyStatus() (The 12 most common are tracked.)
- Number of Safety Events
- Cycle Count at Last Safety Event(s)
- Charging Events
- Number of Valid Charge Terminations (That is, the number of times [VCT] is set.)
- Cycle Count at Last Charge Termination
- Power Events
- Number of Resets, Partial Resets, and Watchdog Resets
- Number of shutdowns
- Cell Balancing (This data is stored with a resolution of 2 hours up to a limit of 510 hours.)
- Cell Balancing Time each Cell
- Temperature
- Max/Min Cell Temp
- Delta Cell Temp (max delta cell temperature across the thermistors that are used to report cell temperature)
- Max/Min Int Temp Sensor
- Max FET Temp
- Time (This data is stored with a resolution of 2 hours.)
- Total runtime
- Time spent different temperature ranges