SLUUAQ3A April 2016 – October 2022 BQ4050
Class | Subclass | Name | Type | Min | Max | Default | Unit | Description |
---|---|---|---|---|---|---|---|---|
Gas Gauging | CEDV Cfg | EMF | U2 | 0 | 65535 | 3743 | — | This is the no-load cell voltage calculated and based on higher than the highest cell EDV threshold. |
Gas Gauging | CEDV Cfg | C0 | U2 | 0 | 65535 | 149 | — | This value is the no-load capacity related EDV adjustment factor. |
Gas Gauging | CEDV Cfg | R0 | U2 | 0 | 65535 | 867 | — | First order rate dependency factor, accounting for battery impedance adjustment |
Gas Gauging | CEDV Cfg | T0 | U2 | 0 | 65535 | 4030 | — | Adjusts for the variation of impedance with battery temperature |
Gas Gauging | CEDV Cfg | R1 | U2 | 0 | 65535 | 316 | — | Adjusts for the variation of impedance with battery capacity |
Gas Gauging | CEDV Cfg | TC | U1 | 0 | 255 | 9 | — | Adjusts for the variation of impedance for cold temperature (T < 23°C) |
Gas Gauging | CEDV Cfg | C1 | U1 | 0 | 255 | 0 | — | This value is the desired reserved battery capacity remaining at EDV0. |
Gas Gauging | CEDV Cfg | Age factor | H2 | 0 | 255 | 0 | — | Allows the algorithm to compensate EDV detection for cell aging |
Gas Gauging | CEDV Cfg | Fixed EDV0 | H2 | 0 | 32767 | 3031 | — | This value is the EDV0 threshold if [CEDV] is clear in CEDV Config. |
Gas Gauging | CEDV Cfg | Fixed EDV0 Delay | U1 | 0 | 255 | 0 | — | Delay time enforced before qualifying EDV0 is met. |
Gas Gauging | CEDV Cfg | Fixed EDV1 | H2 | 0 | 32767 | 3385 | — | This value is the EDV1 threshold if [CEDV] is clear in CEDV Config. |
Gas Gauging | CEDV Cfg | Fixed EDV1 Delay | H2 | 0 | 255 | 0 | — | Delay time enforced before qualifying EDV1 is met. |
Gas Gauging | CEDV Cfg | Fixed EDV2 | H2 | 0 | 32767 | 3501 | — | This value is the EDV2 threshold if [CEDV] is clear in CEDV Config. |
Gas Gauging | CEDV Cfg | Fixed EDV2 Delay | H2 | 0 | 255 | 0 | — | Delay time enforced before qualifying EDV2 is met. |
Gas Gauging | CEDV Cfg | Battery Low % | U1 | 0 | 65535 | 700 | 0.1% | This value should be a capacity value that corresponds to the first or highest voltage point EDV2. |
Gas Gauging | CEDV Cfg | Learning Low Temp | U1 | 0 | 255 | 119 | 0.1C | This is the minimum temperature above which discharge must maintain to qualify for a capacity learning. |
Gas Gauging | CEDV Cfg | Overload Current | I2 | 0 | 32767 | 5000 | mA | This is the value for upper current range for EDV detection. Beyond this value EDV detection is halted. |
Gas Gauging | CEDV Cfg | Self Discharge Rate | U1 | 0 | 255 | 20 | 0.01%/day | This is an estimation for the self-discharge of the battery. |
Gas Gauging | CEDV Cfg | Electronic Load | I2 | 0 | 255 | 0 | 3 µA | This is the value set to a discharge rate determined by the battery electronics current consumption. |
Gas Gauging | CEDV Cfg | Near Full | I2 | 0 | 32767 | 200 | mAh | This value sets the discharge condition for qualified capacity learning. |
Gas Gauging | CEDV Cfg | Reserve capacity | I2 | 0 | 32767 | 0 | mAh | Determines (if Load Mode = 0) how much actual remaining capacity exists when the gas gauge reports zero RemainingCapacity() before reaching Termination Voltage. |
Gas Gauging | CEDV Cfg | Chg Eff | U1 | 0 | 100 | 100 | % | This value compensates for efficiency loss during charging when estimating total capacity value. |
Gas Gauging | CEDV Cfg | Dsg Eff | U1 | 0 | 100 | 100 | % | This value compensates for efficiency loss during discharging when estimating total capacity value. |