SLUUCA6 October 2021 BQ27Z746
The device can detect cell overvoltage in batteries and protect cells from damage by preventing further charge.
The protection detection threshold may be influenced by the temperature settings of the advanced charging algorithm and the measured temperature.
Status | Condition | Action |
---|---|---|
Normal,
ChargingStatus()[UT] or [LT] = 1 | Voltage() < COV:Threshold Low Temp | SafetyAlert()[COV] = 0 |
Normal,
ChargingStatus()[STL] or [STH] = 1 | Voltage() < COV:Threshold Standard Temp | |
Normal,
ChargingStatus()[RT] = 1 | Voltage() < COV:Threshold Rec Temp | |
Normal,
ChargingStatus()[HT] or [OT] = 1 | Voltage() < COV:Threshold High Temp | |
Alert,
ChargingStatus()[UT] or [LT] = 1 | Voltage() ≥ COV:Threshold Low Temp | SafetyAlert()[COV] = 1 BatteryStatus()[TCA] = 1 |
Alert,
ChargingStatus()[STL] or [STH] = 1 | Voltage() ≥ COV:Threshold Standard Temp | |
Alert,
ChargingStatus()[RT] = 1 | Voltage() ≥ COV:Threshold Rec Temp | |
Alert,
ChargingStatus()[HT] or [OT] = 1 | Voltage() ≥ COV:Threshold High Temp | |
Trip,
ChargingStatus()[UT] or [LT] = 1 | Voltage() ≥ COV:Threshold Low Temp for COV:Delay duration | SafetyAlert()[COV] = 0 SafetyStatus()[COV] = 1 BatteryStatus()[TCA] = 0 OperationStatus()[XCHG] = 1 |
Trip,
ChargingStatus()[STL] or [STH] = 1 | Voltage() ≥ COV:Threshold Standard Temp for COV:Delay duration | |
Trip,
ChargingStatus()[RT] = 1 | Voltage() ≥ COV:Threshold Rec Temp for COV:Delay duration | |
Trip,
ChargingStatus()[HT] or [OT] = 1 | Voltage() ≥ COV:Threshold High Temp for COV:Delay duration | |
Recovery,
ChargingStatus()[UT] or [LT] = 1 | SafetyStatus()[COV] = 1 AND Voltage() ≤ COV:Recovery Low Temp for COV:Recovery Delay | SafetyStatus()[COV] = 0 BatteryStatus()[TCA] = 0 OperationStatus()[XCHG] = 0 |
Recovery,
ChargingStatus()[STL] or [STH] = 1 | SafetyStatus()[COV] = 1 AND Voltage() ≤ COV:RecoveryStandard Temp for COV:Recovery Delay | |
Recovery,
ChargingStatus()[RT] = 1 | SafetyStatus()[COV] = 1 AND Voltage() ≤ COV:Recovery Rec Temp for COV:Recovery Delay | |
Recovery,
ChargingStatus()[HT] or [OT] = 1 | SafetyStatus()[COV] = 1 AND Voltage() ≤ COV:Recovery High Temp for COV:Recovery Delay |