SLUUCH2 March 2021 BQ40Z50-R2
The BQ40Z50-R4 device has an overtemperature protection to limit the FET temperature.
Status | Condition | Action |
---|---|---|
Normal | FET Temperature in DAStatus2()<OTF:Threshold | SafetyAlert()[OTF] = 0 |
Alert | FET Temperature in DAStatus2()≥OTF:Threshold | SafetyAlert()[OTF] = 1 BatteryStatus()[TDA] = 1, [TCA] = 1 |
Trip | FET Temperature in DAStatus2() ≥ OTF:Threshold for OTF:Delay duration | SafetyAlert()[OTF] = 0 SafetyStatus()[OTF] = 1 BatteryStatus()[OTA] = 1 BatteryStatus()[TDA] = 0, [TCA] = 0 OperationStatus()[XCHG][XDSG] = 1,1 if FET Options[OTFET] = 1 |
Recovery | SafetyStatus()[OTF] AND FET Temperature in DAStatus2() ≤ OTF:Recovery | SafetyStatus()[OTF = 0 BatteryStatus()[OTA] = 0 BatteryStatus()[TDA] = 0, [TCA] = 0 OperationStatus()[XCHG][XDSG] = 0,0 |