SLUUCN1C June   2022  – December 2022 UCC28C50 , UCC28C50-Q1 , UCC28C51 , UCC28C51-Q1 , UCC28C52 , UCC28C52-Q1 , UCC28C53 , UCC28C53-Q1 , UCC28C54 , UCC28C54-Q1 , UCC28C55 , UCC28C55-Q1 , UCC28C56H , UCC28C56H-Q1 , UCC28C56L , UCC28C56L-Q1 , UCC28C57H , UCC28C57H-Q1 , UCC28C57L , UCC28C57L-Q1 , UCC28C58 , UCC28C58-Q1 , UCC28C59 , UCC28C59-Q1

 

  1.   Trademarks
  2. 1General Texas Instruments High Voltage Evaluation (TI HV EVM) User Safety Guidelines
  3. 2Description
    1. 2.1 EVM Electrical Performance Specifications
  4. 3Schematic Diagram
  5. 4EVM Setup and Operation
    1. 4.1 Recommended Test Equipment
    2. 4.2 External Connections
      1. 4.2.1 Setup and Connection of Test Equipment
      2. 4.2.2 Power On for the First Time
    3. 4.3 EVM Test Points
  6. 5Performance Data
    1. 5.1  Efficiency Versus Load, 10% to 100% Load
    2. 5.2  Efficiency Versus VIN at 100% Load
    3. 5.3  Power Loss Versus Load, 10% to 100% Load
    4. 5.4  Load Regulation, 10% to 100% Load
    5. 5.5  Light Load Regulation, 0-mA to 200-mA Load
    6. 5.6  Line Regulation, Various Loads
    7. 5.7  Startup Waveforms
    8. 5.8  Shutdown Waveforms
    9. 5.9  Output Voltage Ripple
    10. 5.10 Steady State Switching Waveforms
    11. 5.11 Transient Load Waveforms
    12. 5.12 Over Current and Short Circuit Protections
    13. 5.13 Stability Measurements
    14. 5.14 Thermal Measurements
  7. 6Assembly and Printed Circuit Board (PCB)
  8. 7Bill of Materials (BOM)
  9. 8Revision History

Setup and Connection of Test Equipment

  1. Before connecting it to the EVM, turn on and adjust the VIN power supply to 50 V and set its current limit to 1.5 A.

  2. Turn off/disable the VIN power supply.

  3. Connect the VIN power supply to J2 (VIN+) and J1 (GND).

  4. Connect the variable load to J4 (VOUT+) and J3 (ISO_GND).

  5. Set the load to the constant current (CC) and 0.25 A. Enable the load.