7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
COV | CUV | SCD | OCD1 | OCD2 | OCC | CURLATCH | REGOUT |
Description: Provides individual fault signals when enabled safety faults have triggered.
Bit | Field | Description |
---|---|---|
7 | COV | Cell Overvoltage Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
6 | CUV | Cell Undervoltage Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
5 | SCD | Short Circuit in Discharge Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
4 | OCD1 | Overcurrent in Discharge 1 Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
3 | OCD2 | Overcurrent in Discharge 2 Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
2 | OCC | Overcurrent in Charge Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
1 | CURLATCH | Current Protection Latch Safety Fault
0 = Indicates the number of attempted current protection recoveries has not yet exceeded the latch count. 1 = Indicates the number of attempted current protection recoveries has exceeded the latch count, and autorecovery based on time is disabled. |
0 | REGOUT | REGOUT Safety Fault
0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |