SLUUD50 October 2024 BQ27Z758
Class | Subclass | Name | Type | Min | Max | Default | Unit | Description |
---|---|---|---|---|---|---|---|---|
Protections | OCC | Threshold | I2 | –32768 | 32767 | 12000 | mA | Overcurrent in Charge trip threshold |
Protections | OCC | Delay | U1 | 0 | 255 | 1 | s | Overcurrent in Charge trip delay |
Protections | OCC | Recovery Threshold | I2 | –32768 | 32767 | 200 | mA | Overcurrent in Charge recovery threshold |
Protections | OCC | Recovery Delay | U1 | 0 | 255 | 10 | s | Overcurrent in Charge recovery delay |