SLVAFG6A December   2022  – November 2023 TPS25762-Q1 , TPS25772-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 Terms and Abbreviations
  5. 2 SPM Engine Overview
  6. 3Multi-Port Power Allocation Policy
    1. 3.1 Assured Capacity Policy
    2. 3.2 Shared Capacity Policy
      1. 3.2.1 Fair Share Power Policy
        1. 3.2.1.1 Blind Sink Support
    3. 3.3 Hybrid Mode
  7. 4Power Foldback Policy
    1. 4.1 Thermal Foldback Operation
    2. 4.2 Engine Start or Stop Transition Management
      1. 4.2.1 Engine Start or Stop Power Foldback Operation Example
  8. 5Multi-Port Power Allocation Policy Examples
    1. 5.1 Assured Capacity Policy Example
    2. 5.2 Fair Share Power Policy Example
      1. 5.2.1 FSP Policy Example – Blind Sink Support
      2. 5.2.2 FSP Policy Example – Blind Sink Support with Max Power
    3. 5.3 Hybrid Mode Example
  9. 6References
  10. 7Revision History

Power Foldback Policy

The TPS257xx-Q1 PD controllers support Power Foldback Policies based on system temperature and VIN supply voltage levels. The Power Foldback Policies are managed by the integrated SPM Engine alongside the Multi-Port Power Allocation Policy (in the case of the TPS25772-Q1). Upon entry into a Power Foldback condition, the SPM uses the Total USB VBUS Power for the corresponding Power Foldback phase the TPS257xx-Q1 has entered then distributes port power accordingly.