Ensure that the switches S1 (EN1), S2 (EN2), and S3 (EN) are in OFF position.
Ensure that the shunt jumpers for JP1 (TRIP) is set 7-pin to 8-pin (VREG5; Vocl = 60 mV, Discharge-enabled), JP2 (FUNC) is set 1-pin to 2-pin (GND; UVP/OVP-enabled), and JP3, JP4 are set 3-pin to 4-pin (VREF2; Auto-skip).
Apply appropriate VIN voltage to VIN and GNDI terminals. Check that VREG3 (3.3V-LDO) starts up.
Turn S3 (EN) to ON. Check that VREG5 (5V-LDO) and VREF2 (2V-Ref) start up.
When S1 (EN1) is turned to ON, CH1-output starts up.
When S2 (EN2) is turned to ON, CH2-output starts up.