Working at an ESD workstation, make sure that any
wrist straps, bootstraps, or mats are connected referencing the user to earth
ground before power is applied to the EVM. An electrostatic smock and safety
glasses should also be worn.
Prior to connecting the DC input source,
VIN, it is advisable to limit the source current from
VIN to 2.0-A maximum. Make sure VIN is initially set
to 0 V and connected as shown in Figure 4-1.
Connect the ammeter A1 (0-A to 5-A range) between
VIN and J1 as shown in Figure 4-1.
Connect voltmeter V1 to TP1 and TP2 as shown in Figure 4-1.
Connect LOAD1 to J2 as shown in Figure 4-1. Set LOAD1 to constant current mode to sink 0 Adc before VIN is
applied.
Connect voltmeter V2 across TP3 and TP4 as shown
in Figure 4-1.
Connect LOAD2 to J3 as shown in Figure 4-1. Set LOAD2 to constant current mode to sink 0 Adc before VIN is
applied.
Connect voltmeter V3 across TP18 and TP19 as
shown in Figure 4-1.
Place a fan as shown in Figure 4-2 and turn it on, making sure air is flowing across the EVM.