Follow the instructions to verify undervoltage levels of the device:
- Set jumpers J3 and J9 in 2-3 position to set UVLO level at 43 V.
- Set the load resistance to 96 Ω ±1 Ω and the power supply voltage to 48 V. Enable the power
supply and the load.
- Reduce the CH1 input voltage and verify that VOUT1 reduces as VN1 reduces and
drops to zero when VIN1 falls below 43 V ±1 V (CH1 UVLO limit).
- Similarly, reduce the CH2 input voltage and verify that VOUT2 reduces as VN2
reduces and drops to zero when VIN2 falls below 43 V ±1 V (CH2 UVLO limit).
- Verify that CH1 and CH2 FLTb red LEDs (D3/D7) turn on whenever the supply voltage reaches UVLO limits of the respective channels.
- Disable the power supply and the load.