Use the following instructions to verify power limit response of TPS1641o on CH1:
- Make J3 OPEN.
Set J4 in 1-2 position to set transient blanking time of 5 ms
- Set J5 in 3-4 position to set 13.7-W power limit.
- Set the input supply voltage VIN to 12 V and current limit of 3 A. Enable the power supply.
- Apply load of 1-A at the output.
- Now, apply overload to verify the power limiting behavior of TPS16410.
Figure 5-3 shows power limit response of TPS16410 on the TPS1641EVM Evaluation Board.
Figure 5-3 Power Limit Response of TPS16410 for 13.7-W Power Limit Setting