SLVUCK5 December 2022 TLVM23625
The data was tested on the EVM, with L1 changed to 4.7 uH. The EVM was configured for 1-MHz operation and 5 VOUT, and was measured at 12 VIN and a 2.5-A load.
The data was tested on the EVM, with L1 changed to 4.7 uH. The EVM was configured for 1-MHz operation and 5 VOUT, and was measured at 24 VIN and a 2.5-A load.
12 VIN, 2.2 MHz, 2-A load (continuous)
12 VIN, 1 MHz, 2-A load (continuous)
12 VIN, 500 kHz, 2-A load (continuous)
24 VIN, 2.2 MHz, 2-A load (continuous)
24 VIN, 1 MHz, 2-A load (continuous)
24 VIN, 500 kHz, 2-A load (continuous)