To setup the software configuration,
follow the instructions below.
- Open the Application Customization Tool and
select one of the following TPS25751D + BQ configurations below:
- Fill out the questionnaire from
Q2 to Q10, refer to Section 3.3.3 for more details on each question configuration. All the
questions must be filled out to flash or export settings.
- Questions 11 through 18 are for
Battery Charger (BQ) Configurations.
- For Question 11, select
BQ25792/8.
- For Question 12, select the INDPM
configuration for the BQ25792/8EVM.
- For example, if the user
selects "5% - INDPM is set to 5% above the negotiated PD Contract
Current" and TPS25751 negotiates a PD contract at 3A, the INDPM is set
to 3.15A.
- This questionnaire
configures register 0x06 - IINDPM of BQ25792/8.
- For Question 13, select the
VINDPM configuration for the BQ25792/8EVM.
- For example, if the user
selects "5% - VINDPM is set to 5% below the negotiated PD Contract
Voltage" and TPS25751 negotiates a PD contract at 5V, the VINDPM is set
to 4.75V.
- This questionnaire
configures register 0x05 - VINDPM of BQ25792/8.
- For question 14, enter the Charge
Voltage in units of Voltage (3V through 18.8V, 10mV/bit).
- This questionnaire
configures register 0x01 - VREG of BQ25792/8.
- For question 15, enter the Charge
Current in units of Ampere (0.05A through 5A, 10mA/bit)
- This questionnaire
configures register 0x03 - ICHG of BQ25792/8.
- For question 16, enter the Charge
Termination Current Limit in units of Ampere (0.04A through 1A, 40mA/bit).
- This questionnaire
configures register 0x09 - ITERM of BQ25792/8.
- For question 17, enter the
Precharge Current Limit in units of Ampere (0.04A through 2A, 40mA/bit)
- This questionnaire
configures register 0x08 - IPRECHG of BQ25792/8.
- For question 18, enter the Dead Battery Clear Threshold in units of Voltage
(2.88V through 19.2V, 64mV/bit)
- This questionnaire
configures register 0x27 - Global System Configuration of TPS25751 and
set "Enable Dead Battery Clear [111]" to '1'.
- Upon boot-up from dead
battery mode (TPS25751 receives power from VBUS first instead of
VIN_3V3), TPS25751 reads register 0x3B - ADC VBAT of BQ25792/8.
- If VBAT voltage is
greater or higher than set threshold in Q18, TPS25751 automatically
clear the dead battery flag, otherwise the dead battery flag remains.
Refer to the TPS25751 Technical Reference Manual for
details.
- Refer to Section 3.3.6 for flashing the configuration or exporting the binary.