SNLA266A January 2016 – December 2023 DP83822H , DP83822HF , DP83822I , DP83822IF , DP83825I , DP83826E , DP83826I
Purpose: To verify that the differential output voltage is within the specified bounds.
Pass Condition: The differential output voltage must be within a positive range of 950 mV to 1050 mV and negative range of –950 mV to –1050 mV. The positive and negative peak magnitudes must also be within 2% of each other.