SNLA423 March   2023 DP83826E

 

  1. 1Trademarks
  2. 2DP83826 Application Overview
  3. 3Troubleshooting the Application
    1. 3.1 Read and Check Register Values
    2. 3.2 Schematic and Layout Checklist
    3. 3.3 Component Checklist
    4. 3.4 Peripheral Pin Checks
      1. 3.4.1 Power Supplies
      2. 3.4.2 Probe the XI Clock
      3. 3.4.3 Probe the RESET_N Signal
      4. 3.4.4 Probe the Strap Pins During Initialization
      5. 3.4.5 Probe the Serial Management Interface Signals (MDC, MDIO)
      6. 3.4.6 Probe the MDI Signals
    5. 3.5 Link Quality Check
    6. 3.6 Built-In Self Test with Various Loopback Modes
    7. 3.7 Debugging MAC Interface
    8. 3.8 Tools and References
      1. 3.8.1 DP83826 Register Access
      2. 3.8.2 Extended Register Access
      3. 3.8.3 Application Note References
  4. 4Conclusion
  5. 5Revision History

Power Supplies

The power supplies are the first key item to check. Power up the device and perform DC measurement of the supplies as close to the pin as possible. Confirm that each measurement is within the limits defined in the Recommended Operating Conditions section of the datasheet.

GUID-F7BC924A-A904-4744-95D3-163C209FF5A2-low.gifFigure 3-1 Power Supply Decoupling Recommendation