After establishing a valid link, confirming the key status register values and visually verifing that the link LED is lit, the next data transfer debug step is to check the MAC Interface.
There are several possible sources of link problems:
IEEE compliance measurements can be made to verify the signaling. For details on these measurements, please refer to the application note DP83826 Ethernet Compliance Testing (SNLA239).
With the PHY powered and connected to a link partner, the following registers can be read from to determine the health of the link:
CHANNEL | REGISTER ADDRESS |
---|---|
A | 0x225 |
For a given channel, read the register value to determine the MSE (Mean Square Error), convert to decimal, and refer to the following table to determine link quality:
LINK QUALITY | MSE RANGE |
---|---|
Excellent | < 522 |
Good | 522 - 827 |
Poor | > 827 |