SNLU223D August   2017  – February 2023 DS90UB954-Q1

 

  1.   DS90UB954-Q1EVM Deserializer User's Guide
  2. Trademarks
  3. Introduction
  4. Quick Start Guide
    1. 3.1 System Requirements
      1. 3.1.1 Included Components
      2. 3.1.2 Additional Required Components
    2. 3.2 Applications Diagram
    3. 3.3 Major Components of DS90UB954-Q1EVM
    4. 3.4 DS90UB954-Q1EVM Setup
  5. DS90UB954-Q1EVM Board Configuration
    1. 4.1 Default Configuration
    2. 4.2 Power Supply
    3. 4.3 Power-over-Coax Interface
    4. 4.4 MIPI CSI-2 Output Signals
    5. 4.5 FPD-Link III Signals
    6. 4.6 I2C Interface
    7. 4.7 Control Interface
  6. Enable and Reset
  7. Use with DS90UB936-Q1
  8. Typical Connection and Test Equipment
  9. Termination Device
  10. Typical Test Setup
  11. 10Equipment References
  12. 11Cable References
  13. 12Software for DS90UB954Q1-EVM Evaluation - Analog LaunchPAD (ALP) Software Setup
    1. 12.1 System Requirements
    2. 12.2 Download Contents
    3. 12.3 Installation of the ALP Software
    4. 12.4 Startup - First Launch
  14. 13Using ALP and DS90UB954 Profile
    1. 13.1 Information Tab
    2. 13.2 Registers Tab
    3. 13.3 Registers Tab - Address 0x00 Expanded
      1. 13.3.1 Port Specific Registers
      2. 13.3.2 36
    4. 13.4 Saving and Loading Register Settings
    5. 13.5 Scripting Tab
      1. 13.5.1 Example Functions
        1. 13.5.1.1 Local I2C Reads/Writes
        2. 13.5.1.2 General I2C Reads/Writes:
        3. 13.5.1.3 I2C Reads/Writes with Multi-Byte Register Addresses
    6. 13.6 GPIO Tab
    7. 13.7 Forwarding Tab
    8. 13.8 CSI Registers Tab
    9. 13.9 Remote Registers Tab
  15. 14Troubleshooting ALP Software
    1. 14.1 ALP Does Not Detect The EVM
    2. 14.2 USB2ANY Firmware Issues
  16. 15DS90UB954-Q1EVM PCB Schematics, Layout and Bill of Materials - DS90UB954-Q1EVM Schematic
  17. 16DS90UB954-Q1 EVM PCB Layout
  18. 17DS90UB954-Q1EVM Bill of Materials
  19. 18Revision History

Startup - First Launch

Make sure all the software has been installed and the hardware is powered on and connected to the PC. Execute “Analog LaunchPAD” shortcut from the start menu. The default start menu location is under All Programs > Texas Instruments > Analog LaunchPAD vx.x.x > Analog LaunchPAD to start MainGUI.exe.

GUID-F128EDD4-09E2-458E-8ADB-692AD3FAE3DD-low.pngFigure 12-1 Launching ALP Splash Screen

Upon first launch of the Analog LaunchPAD utility, the default device will be DS90UB925. The active device can be seen as highlighted in #SNLU2234207, here showing the DS90UB954 as active. If the active device is already set to DS90UB954 you may skip to GUID-DB97BE2B-5271-4584-B672-369F28C75A42.html#GUID-DB97BE2B-5271-4584-B672-369F28C75A42.

GUID-6A178787-6DB2-41F0-9793-2EE01E87EA82-low.pngFigure 12-2 Initial ALP Screen

Follow the steps beginning with #T4697723-17 to change the ALP profile to DS90UB954.

GUID-6C921A49-7E96-4240-BF93-CBFD2C4F2846-low.pngFigure 12-3 Select USB2ANY/Aardvark Setup to Change Profile

Select the active profile and click "Remove". Scroll down the list of available profiles to DS90UB954, click to highlight it, click "Add", and click "Ok".

GUID-CC113297-D6D6-4757-84E6-5806EE2B78D8-low.pngFigure 12-4 ALP Profiles Dialog
GUID-64709565-794F-4909-867F-52F495144C40-low.pngFigure 12-5 ALP Profiles Dialog (continued)