SNLU262A december 2019 – june 2023 DP83826I
N0. | TEST CASES | APPLICATIONS | HOW TO USE |
---|---|---|---|
1 | MII/RMII to Copper | Run traffic between MII/RMII and Copper. | Connect to DP83826 EVM or MAC System using Header pins. |
Perform IEEE and UNH compliance testing | Using onboard MSP430 and software. | ||
Run EMI/EMC Test on EVM | Use internal PRBS and loopback. Onboard MSP430 can be used for register access. | ||
Measure Power Dissipation | Connect external power supplies. | ||
External MAC loopback | Connect external MAC to headers and use MAC loopback register settings | ||
50MHz output clock | Optional Clock out SMA | ||
2 | Loopback | Data received by the PHY can be looped back through the interface without needing a MAC. | Use onboard MSP430 to enable loopback. |
3 | Repeater Mode | RMII back to back as range extender. | Two EVMs can be connected back to back using custom header cable. |
4 | Low Power modes | Demonstrate EEE | Use onboard MSP430 to enable EEE. |
Demonstrate Sleep and Power down mode | Use onboard MSP430 to activate low power mode |