SNOU170A August   2020  – December 2020

 

  1.   Trademarks
  2. 1Introduction
  3. 2Features
  4. 3EVM Specifications
  5. 4Recommended Equipment
  6. 5Quick Start Procedure
  7. 6Board Setup
    1. 6.1 Supply Voltage
    2. 6.2 Inputs
    3. 6.3 Outputs
  8. 7Layout Guidelines
  9. 8Schematic
  10. 9Bill of Materials

Outputs

R4 is only needed if it is preferred to measure the LVDS output directly across the component, or if the board is being used to feed directly to the inputs of another interconnect device such as an FPGA. Otherwise it can be left uninstalled.

GUID-20200803-CA0I-NBXS-HR3N-BX6WF0BN5XCV-low.gif Figure 6-3 Output Side Schematic

J8 and J9 are installed with 0.1 uF capacitors. If probes are unavailable to measure the LVDS output across R4 or with a differential probe, these capacitors allow for the AC portion of the signal to be seen on a 50 Ω terminated scope. If equipment is available to measure the LVDS output with a respect to R4 or with a differential probe, then J8 and J9 can be replaced with 0 Ω resistors to keep the DC integrity of the output signal.

  

GUID-20200803-CA0I-LZSK-PXPN-DV6XM3KQCLG3-low.png Figure 6-4 Differential Output of TLV3604EVM.