SNVA958 April 2020 LP8863-Q1
The LP8863-Q1 supports eight valid string configurations for auto-detection, as shown in Table 1. The auto-detection could not work properly if using invalid string configuration, which may cause the following problems:
For example, use an invalid configuration - LED0~2 tied together LED3~5 tied to ground.
This configuration is automatically detected as LED0~2 tied together LED3~5 tied together mode (AUTO_LED_STRING_CFG = 6h), as shown in Figure 3(a) and Figure 3(b). For LP8863-Q1 device, unused channels are automatically disabled and do not generate open/short LED fault. But, LED3~5 are wrongly detected being used here, the device keeps detecting LED3~5 faults. After the boost ramps to maximum level, the headroom voltage on LED3~5 is detected below minimum level (because LED3~5 tied to ground), which triggers LED3~5 open faults. The open detection process can be seen in Figure 3(c).
(a) LED String Auto-Detection Flow |
(b) LED String Auto-Detection Waveform |
(c) Start-Up Waveform |