Power Supply: The input
voltage source (VIN) must be a variable supply capable of 0V to 10V and source
at least 10A.
Multi-meters:
Voltmeter 1: Input voltage. Connect from VIN+ to
VIN–.
Voltmeter 2: Output voltage. Connect from VOUT+ to
GND.
Ammeter 1: Input current. Must be able to handle 10A.
Shunt resistor can be used as needed.
Ammeter 2: Output current. Must be able to handle 2A.
Shunt resistor can be used as needed.
Electronic Load: The load
is constant resistance (CR) or constant current (CC) capable and safely handles
2A at 12V.
Oscilloscope: 20MHz
bandwidth and AC coupling. Measure the output voltage ripple directly across an
output capacitor with a short ground lead. TI does not recommend to use a
long-leaded ground connection due to the possibility of noise being coupled into
the signal. To measure other waveforms, adjust the oscilloscope as needed.