SPRUHJ1I January 2013 – October 2021 TMS320F2802-Q1 , TMS320F28026-Q1 , TMS320F28026F , TMS320F28027-Q1 , TMS320F28027F , TMS320F28027F-Q1 , TMS320F28052-Q1 , TMS320F28052F , TMS320F28052F-Q1 , TMS320F28052M , TMS320F28052M-Q1 , TMS320F28054-Q1 , TMS320F28054F , TMS320F28054F-Q1 , TMS320F28054M , TMS320F28054M-Q1 , TMS320F2806-Q1 , TMS320F28062-Q1 , TMS320F28062F , TMS320F28062F-Q1 , TMS320F28068F , TMS320F28068M , TMS320F28069-Q1 , TMS320F28069F , TMS320F28069F-Q1 , TMS320F28069M , TMS320F28069M-Q1
During the Lock Rotor state, the state machine waits for the user to re-enable the controller once the motor's shaft has been locked (Figure 7-38). Locking the rotor is required to identify the rest of the ACIM motor parameters: series inductance (Ls) and rotor resistance (Rr).
The state machine will remain in this state indefinitely until the user re-enables the controller by calling the following instruction:
// enable or disable the control
CTRL_setFlag_enableCtrl(ctrlHandle, TRUE);