This specifies the number of scan data patterns within a self-test interval. The pattern counts can vary from a minimum of 2 to a maximum of 1024.
patt_count[9:0] | Patterns per Interval |
---|---|
00_0000_0000 | Not a valid interval [defaults to 2 patterns per interval] |
00_0000_0001 | 2 patterns per interval |
00_0000_0010 | 3 patterns per interval |
... | ... |
11_1111_1110 | 1023 patterns per interval |
11_1111_1111 | 1024 patterns per interval |