SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Receive frame tag and user data register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
FSI_RX0 | 5029 000Eh |
FSI_RX1 | 5029 100Eh |
FSI_RX2 | 502B 000Eh |
FSI_RX3 | 502B 100Eh |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
USER_DATA | |||||||
R | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED_1 | FRAME_TAG | ZERO | |||||
R | R | R | |||||
0h | 0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:8 | USER_DATA | R | 0h | Received User Data This field contains the 8-bit user data field of the last successfully received frame. |
7:5 | RESERVED_1 | R | 0h | Reserved |
4:1 | FRAME_TAG | R | 0h | Received Frame Tag This field contains the 4-bit frame tag from the last successfully received frame. This is intentionally shifted into bits 4:1 so that the register can be used as a 32-bit address index based on the received tag. |