SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Receive CRC info of received and computed CRC.
Return to Summary Table
Instance Name | Physical Address |
---|---|
FSI_RX0 | 5029 0016h |
FSI_RX1 | 5029 1016h |
FSI_RX2 | 502B 0016h |
FSI_RX3 | 502B 1016h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
CALC_CRC | |||||||
R | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RX_CRC | |||||||
R | |||||||
0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:8 | CALC_CRC | R | 0h | Harware Calculated CRC Value This bitfield contains the CRC value that was calculated on the last received data. The contents of this bitfield are valid only when data frames are received. Note: The contents of this bitfield are invalid for ping and error frames. |
7:0 | RX_CRC | R | 0h | Received CRC Value This bitfield contains the CRC value that was last received a frame. The contents of this bitfield are valid only when data frames are received. Note: The contents of this bitfield are invalid for ping and error frames. |