SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
The Policing Table Control is used to read or write the selected policing/classifier entry. The selected policing/classifier entry is only read or written after this register is written based on the value of the ~iwrite_enable bit.
Return to Summary Table
Instance Name | Physical Address |
---|---|
CPSW0 | 5283 E120h |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
WRITE_ENABLE | RESERVED | ||||||
R/W | NONE | ||||||
0h | 0h | ||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED | POL_TBL_IDX | ||||||
NONE | R/W | ||||||
0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31 | WRITE_ENABLE | R/W | 0h | Write Enable - Setting this bit will write the POLICECFG0-7 to the pol_tbl_idx selected policing/classifier entry. Clearing this bit will read the pol_tbl_idx selected policing/classifier entry into the POLICECFG0-7 registers. |
30:5 | RESERVED | NONE | 0h | Reserved |
4:0 | POL_TBL_IDX | R/W | 0h | Policer Entry Index - This field specifies the policing/classifier entry to be read or written. When writing to this field without setting the write_enable=1 will cause the selected policing/classifier entry to be loaded into the POLICECFG0-7 registers. When writing to this field with setting the write_enable=1 will cause the selected policing/classifier entry to be updated from the POLICECFG0-7 registers. |